Loading... Please wait...The Ophthalmology Practice is proud to announce the adoption of the Nidek Mirante - which can not only produce wide-field images of the retina, but also provides OCT (optical coherence tomography) imaging. This ensures patient comfort by using a modern non-invasive technique to look at the layers of the retina.
The ultrawide 163 degrees field-of-view allows viewing of a large portion of the retina layer at the back of the eye, together with the blood vessels, macula, and optic nerve head, all at once. This is done using a scanning laser that quickly goes across the field of vision, rather than a sudden bright flash of light. This improves patient comfort and reduces the after-image washout feeling, especially that patients often need to have their eyes dilated.
The OCT, or Optical Coherence Tomography ability allows us to look at the layers of the retina at a micron (micrometer) level, which provides the gold standard in monitoring for changes when treating for retinal conditions such as age-related macular degeneration (AMD).
Features:
- The ultimate multimodal imaging platform
- For the SLO/OCT model: Color / FA / ICG / Blue-FAF / Green-FAF / Retro mode, OCT / OCT-Angiography
- For the SLO model: Color / FA* / ICG* / Blue-FAF /Green-FAF / Retro mode
- Ultra wide field x ultra HD image
- Unsurpassed color
- Dynamic/Simultaneous FA and ICG
- Unique Retro mode
- HD wide area OCT- Fly Through function
Specifications:
SLO/Fundus image
- Angle of view : Ultra wide field*1 : 163°*2, Standard : 89°*2
- Still image definition (pixel x pixel) : 4,096 x 4,096, 2,048 x 2,048, 1,536 x 1,536, 1,024 x 1,024, 768 x 768, 512 x 512
- Color fundus : Color
- Fundus fluorescence : FA/ICG
- Fundus autofluorescence : Blue-FAF, Green-FAF
- Retro mode : DR/DL/RA
- Red-free : RGB
- Scan speed : Up to 85,000 A-scans/s
OCT sensitivity
- Regular : 85,000 A-scans/s
- Fine : 53,000 A-scans/s
- Ultra fine : 13,250 A-scans/s
- A-scan : 2,048 points, 1,024 points, 512 points, 256 points
- B-scan : 256 scans, 128 scans, 64 scans, 32 scans, 16 scans
- OCT-Angiography: 512 x 512 scans, 256 x 256 scans
- Tracing HD plus
- Scan range : X: 3 to 16.5 mm, Y: 3 to 13.2 mm
- Scan wavelength : 880 nm
Package includes:
- Nidek Mirante SLO/OCT
- USB 3.0 CABLE 1.5 M A-B
- Foot switch
- Chinrest paper
- Objective lens cap
- Power cord (for device main body)
- Blower
- Dust cover
- Chinrest paper pin
- Grip
- Motorized optical table
- Wide-field adapter
- Anterior segment OCT adapter
- Pole-type computer cabinet
- OCT Angiography dongle
- Isolation Transformer
- Mirante installation kit
- Pole-type slim cabinet
- Computer for outside Japan (with USB expansion board)